Low Frequency Solar Inverter 10-20kw

- Double CPU intelligent control technology - The power mode / energy saving mode / battery mode can be set up - Flexible application - Smart fan control, safe and reliable - Cold start function

Products Details

The photovoltaic power generation system occupies about 172 square meters of roof area, and is installed on the roof of residential areas. The converted electric energy can beconnected to the Internet and used for household appliances through inverter. And it is suitable for urban high-rise, multi-storey buildings, Liandong villas, rural houses, etc.1.Double CPU intelligent control technology, excellent performance; 2. Solar priority、Grid power priority mode could be set, application flexible; 3.Imported IGBT module driver, inductive load impact resistance is stronger; 4.Charge current/battery type could be set, convenient and practical; 5.Intelligent fan control, safe and reliable; 6.Pure sine wave AC output, and be adapt to all kinds of loads; 7.LCD display equipment parameter in real-time, operation status be clear at a glance; 8.Output overload, short circuit protection, Battery over voltage/low voltage protection, over temperature protection(85℃), AC charge voltage protection; 9. Export wooden case packing, ensure transportation safety.①--- The mains input ground wire                            ②--- The mains input zero line ③--- The mains input Fire Wire                                  ④--- Output zero line ⑤--- Fire wire output                                                  ⑥--- Output ground ⑦--- Battery positive input                                      ⑧--- Battery negative input ⑨--- Battery charging delay switch                            ⑩--- Battery input switch ⑪--- The mains input switch                                       ⑫--- RS232 communication interface  ⑬--- SNMP communication card
Type:LFI 10KW 15KW 20KW
Rated Power 10KW 15KW 20W
Battery Rated Voltage 96VDC/192VDC/240VDC 192VDC/240VDC
AC Charge Current 20A(Max)
Low Votage Protection 87VDC/173VDC/216VDC
AC Input Voltage Range 88-132VAC/176-264VAC
Frequency 45Hz-65Hz
Output Voltage Range 110VAC/220VAC;±5%(Inversion Mode)
Frequency 50/60Hz±1%( Inversion Mode)
Output Waveform Pure Sine Wave
Switching Time <4ms( Typical Load)
Efficiency >88%(100% resistive load) >91%(100% resistive load)
Overload Over load 110-120%,last on 60S enable overload protection; Over load 160%,last on 300ms then protection;
Protection Function Battery over voltage protection, battery under voltage protection, overload protection, short circuit protection, over temperature protection,etc.
Ambient Temperature for Operation -20℃~+50℃
Ambient Temperature for Storage -25℃ - +50℃
Operation/Storage Conditions 0-90% No Condensation
External dimensions: D*W*H(mm) 555*368*695 655*383*795
G.W.(kg) 110 140 170
Solar inverter is also called a power regulator. Generally speaking, the process of converting DC power into AC power is called an inverter, so the circuit that completes the inverter function is also called an inverter circuit. The device that inverts the process is called a solar inverter. As the core of the inverter device, the inverter switch circuit completes the inverter function through the conduction and observation of the electronic switch.1. Connect and install the equipment in strict accordance with the requirements of the solar inverter operation and maintenance manual. When installing, carefully check whether the wire diameter meets the requirements, whether the components and terminals are loose during transportation, whether the insulation should be well insulated, and whether the grounding of the system meets the regulations. 2. Operate and use in strict accordance with the provisions of the solar inverter operation and maintenance manual. Especially before turning on the machine, pay attention to whether the input voltage is normal. During operation, pay attention to whether the sequence of switching on and off is correct, and whether the indications of the meters and indicator lights are normal. 3. Solar inverters generally have automatic protection for open circuit, overcurrent, overvoltage, overheating, etc., so when these phenomena occur, there is no need to manually stop the inverter. The protection point of automatic protection is generally set at the factory, and no further adjustment is required. 4. There is high voltage in the Solar inverter cabinet, the operator is generally not allowed to open the cabinet door, and the cabinet door should be locked at ordinary times. 5. When the room temperature exceeds 30°C, heat dissipation and cooling measures should be taken to prevent equipment failure and prolong the service life of the equipment.1. Regularly check whether the wiring of each part of the low frequency solar inverter is firm and whether there is any looseness, especially the fan, power module, input terminal, output terminal and grounding should be carefully checked. 2. Once the alarm is shut down, it is not allowed to start up immediately. The cause should be found out and repaired before starting up. The inspection should be carried out in strict accordance with the steps stipulated in the low frequency solar inverter maintenance manual. 3. Operators must be specially trained to be able to judge the cause of general failures and eliminate them, such as skillfully replacing fuses, components and damaged circuit boards. Untrained personnel are not allowed to work and operate the equipment. 4. If an accident that is difficult to eliminate or the cause of the accident is unclear, a detailed record of the accident should be made, and the low frequency solar inverter manufacturer should be notified in time to solve it.